Stationary Cylinder 6 – Suction Port, 7 – Discharge Port
E. Discharge the charging line. f. Close the suction valve g. Run the compressor. h. Open the oil fill valve. i. Close the oil filling valve when the oil is almost empty. k. Open the suction valve. l. Check oil level. 2.2.5. Shut down the machine and perform industrial cleaning. *Practical ...